上海精科儀器,上海精科WZBBC9手持式冰點(diǎn)儀
battery/Coolants/Antifreeze/ Cleaner(冷凍液,冰點(diǎn)儀) 類型 | WZBBC1 | EG:-60oF~32oF | 10oF | 360 |
| PG:-60oF~32oF | 10oF | ||
| BF:1.15~1.30KG/L | 0.01KG/L | ||
WZBBC2 | EG:-50oC~0oC | 10oC | 360 | |
| PG:-50oC~0oC | 5oC | ||
| BF:1.15~1.30KG/L | 0.01KG/L | ||
型號(hào) | 量程 | 精度 | 單價(jià) | |
battery/Coolants/Antifreeze/ Cleaner(冷凍液,冰點(diǎn)儀) | WZBBC2B | EG:-50oC~0oC(0~58.4%) | 10oC | 360 |
| PG:-50oC~0oC(0~62.4%) | 5oC |
| |
| BF:1.15~1.30KG/L | 0.01KG/L |
| |
WZBBC3 | EG:-50oC~0oC | 10oC | 360 | |
| PG:-50oC~0oC | 5oC | ||
| CW:-40oC~0oC | 10oC | ||
| BF:1.15~1.30KG/L | 0.01KG/L | ||
WZBBC4 | EG:-50oC~0oC G13 | 5oC | 360 | |
| PG:-50oC~0oC G11/12 | 5oC | ||
| CW:-40oC~0oC SRFI | 10oC | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC5 | EG:-60oC~0oC | 10oC | 360 | |
| PG:-50oC~0oC | 5oC | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC5B | EG:-60oC~0oC(0~66.6%) | 10oC | 360 | |
| PG:-50oC~0oC(0~62.4%) | 5oC | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC6 | EG:-84oF~32oF | 10oF | 360 | |
| PG:-60oF~32oF | 5oF | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC6B | EG:-84oF~32oF(0~70%) | 10oF | 360 | |
| PG:-60oF~32oF(0~63%) | 5oF | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC7 | EG:-60oC~0oC | 10oC | 360 | |
| PG:-70oC~0oC | 5oC | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC8 | EG:-60oC~0oC | 5oC | 400 | |
| EG:0~* | 5% | ||
| BF:1.10~1.40KG/L | 0.01KG/L | ||
WZBBC9 | PG:-43oC~-2oC | 5oC | 360 | |
| PG: -45~28oF | 10oF | ||
| RI:1.33~1.40 | 0.01ND | ||
WZBBC9B | RI:1.33~1.40 | 0.01ND | 360 |
二、產(chǎn)品應(yīng)用:折光儀具有結(jié)構(gòu)簡(jiǎn)單防震、操作攜帶方便、視野清晰、價(jià)格低廉等優(yōu)點(diǎn)。工業(yè)系列冰點(diǎn)儀應(yīng)用在汽車電瓶液、冷凍液(防凍液)、清洗液的檢測(cè),機(jī)床潤(rùn)滑液、切削液的檢測(cè)
三、產(chǎn)品結(jié)構(gòu):①、折光棱鏡②、蓋板③、校準(zhǔn)螺栓④、光學(xué)系統(tǒng)管路⑤、目鏡(視度調(diào)節(jié)環(huán))
四、使用方法:1)將折光棱鏡①對(duì)準(zhǔn)光亮方向,調(diào)節(jié)目鏡視度環(huán)⑤,直到標(biāo)線清晰為止;2)調(diào)整基準(zhǔn):測(cè)定前首先使標(biāo)準(zhǔn)液(純凈水)、儀器及待測(cè)液體基于同一溫度。掀開蓋板②,然后取1~2滴標(biāo)準(zhǔn)液滴于折光棱鏡上,并用手輕輕按壓蓋板②得出一條明暗分界線。旋轉(zhuǎn)校準(zhǔn)螺栓③使目鏡視場(chǎng)中的明暗分界線與基準(zhǔn)線重合(0%);注:本光學(xué)儀器出廠時(shí)已調(diào)校好,可直接使用。3)掀開蓋板②,用柔軟絨布擦凈棱鏡表面,取1~2滴被測(cè)溶液滴于折光棱鏡上,蓋上蓋板②輕輕按壓,讀取明暗分界線的相對(duì)刻度,即為被測(cè)液體的含量;4)測(cè)量完畢后,直接用潮濕絨布擦去棱鏡表面及蓋板上的附著物,待干燥后,妥善保存起來(lái)。
五、注意事項(xiàng)及維護(hù):1)使用完畢后,嚴(yán)禁用自來(lái)水直接沖洗,避免光學(xué)系統(tǒng)管路進(jìn)水;2)在使用與保養(yǎng)中應(yīng)輕拿輕放,精心保養(yǎng),光學(xué)零件表面不應(yīng)碰傷劃傷;3)本儀器應(yīng)在干燥、無(wú)塵、無(wú)腐蝕性氣體的環(huán)境中保存,以免光學(xué)零件表面發(fā)霉;4)與被測(cè)物接觸的棱鏡屬易耗品,不能修復(fù),請(qǐng)予以理解;5)用戶必須遵守上述使用方法,如造成損壞不在保修范圍內(nèi),不予以保修。