久久国产精品午夜一区_91精品國產高清久久久久久91_?级毛片免费全部播放_欧美色图在线视频一区二区三区_国产综合亚洲一区二区三区_中文字幕熟女网_国产精品男人爽免费视频_九九无码网战_亚洲日本三级电影在线观看_欧美日韩DVD手机在线不卡

| 注冊| 產(chǎn)品展廳| 收藏該商鋪

行業(yè)產(chǎn)品

當(dāng)前位置:
蘇州眾業(yè)電子有限公司>>商機(jī)中心>>供應(yīng)列表>>AP034-力科有源差分探頭
[供應(yīng)]AP034-力科有源差分探頭
舉報(bào)
返回列表頁
  • AP034-力科有源差分探頭
貨物所在地:
江蘇蘇州市
產(chǎn)地:
美國
更新時(shí)間:
2022-01-26 21:00:06
有效期:
2022年1月26日 -- 2022年7月26日
已獲點(diǎn)擊:
352
在線詢價(jià) 收藏產(chǎn)品

(聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝?。?/p>

產(chǎn)品分類品牌分類

更多分類

產(chǎn)品簡介

The AP034 is a high-performance active differential probe. High bandwidth, excellent common-mode rejection ratio

詳細(xì)介紹

力科有源差分探頭英文簡介:

Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.

Wide Dynamic Range: The AP033 provides a range of sensitivities from x10 gain to ÷10 attenuation (even ÷100 with plug-on attenuator) for diverse signals. The sensitivity can be adjusted continuously from 200 µV/div to 1 V/div, when used with a LeCroy oscilloscope.

At high sensitivities, the x10 GAIN and the ÷1 ATTENUATION are selected. This produces 4 nV/√Hz input noise, ±5 V of common mode voltage range (CMVR), and ±400 mV of DC differential offset. At lower sensitivities, the x1 GAIN and ÷10 ATTENUATION are selected, resulting in ±50 V CMVR and ±4 V of differential offset.

The input capacitance is just 2 pF/side (1 pF differential) whenever the ÷10 ATTENUATION is selected. Deflection factors of 2 mV/div to 1 V/div can be obtained with only 2 pF/side input capacitance and ±50 V CMVR.

DC CMRR is greater than 10,000:1 (80 dB) in both ATTENUATION settings.

OFFSET up/down buttons allow OFFSET control from the probe amplifier body. Momentarily holding both buttons will zero the OFFSET.

A supplied AC coupling capacitor head (0.1 µF) allows operation with large common mode or differential DC inputs.

The input attenuator automatically changes from ÷1 to ÷10 when too much common mode signal is sensed. This and a fast input protection circuit also serve to protect the input from potentially damaging signals. When the probe is removed from the oscilloscope or the power is turned off, the ÷10 ATTENUATION is automatically invoked, leaving the inputs protected when not in use.

Gain and Attenuation Selections
The AP033 consists of a probe head with ÷1 or ÷10 attenuation and an amplifier body which attaches to the scope front panel. The amplifier gain can be either x1 and x10. Both the probe head attenuator and amplifier gain are controlled through the ProBus interface. Normally the GAIN and ATTENUATION selections are accomplished by the oscilloscope as shown in the table below.

There are two ways of obtaining x1 gain from the AP033: x1 GAIN with ÷1 ATTENUATION, or x10 GAIN with ÷10 ATTENUATION. The oscilloscope selects the latter of these two options (as shown below) to provide minimum input capacitance and maximum common-mode dynamic range while still leaving low noise operation available at the highest sensitivity.

By using the probe amplifier body control to override the automatic selection, the x1 GAIN with ÷1 ATTENUATION option is readily available for 10 mV, 20 mV and 50 mV/div. CMVR is ±5 V, input capacitance is 5 pF, and noise is 9 nV/√Hz. Similarly, x10 GAIN and ÷10 ATTENUATION can be selected at 2 mV/div and 5 mV/div for 2 pF input C and ±50 V CMVR. The oscilloscope displays the correct deflection factor in all cases.

Using the supplied accessory plug-on attenuator head, gain selections from 100 mV/div to 10 V/div are available.

Input Characteristics
The input capacitance is modeled by 2 pF to ground from each input plus 0.20 pF from input to input when the ÷10 ATTENUATION is selected. This is equivalent to 1.20 pF differential input capacitance. With ÷1 ATTENUATION, the differential input capacitance is 2.7 pF.

Input resistance is 1 Mohm at all GAIN and ATTENUATOR settings, including the accessory plug-on attenuator head.

An AC coupling plug-on accessory features a 0.1 µF coupling capacitor for each input. The low-frequency CMRR is reduced.

Autobalance

Holding both offset buttons down for two seconds with the input connections removed invokes Autobalance. This provides the highest accuracy on all ranges by removing residual DC offset from the probe.

Low Noise

At full gain, the noise is less than 4 nV/√Hz, the lowest of any available differential probe.

Common Mode Sensing and Input Protection

It is not uncommon for a differential amplifier to be connected to a signal whose common- mode voltage exceeds the amplifier''s common-mode range. Faulty readings, including total loss of signal, can result. The AP033 senses when signals exceed ±5.5 V and switches its input attenuator into the signal path. The oscilloscope shows the new deflection factor, and the probe continues to work.

The same mechanism protects the probe from damage due to large input signals. The probe amplifier is protected from large, fast-rising signals until the input attenuator can provide permanent protection. This takes about 1 ms. With the input attenuator in place, the input can withstand 200 V DC indefiniy.
 

力科有源差分探頭 圖片展示:

 產(chǎn)品實(shí)圖

 

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
二維碼 意見反饋
在線留言
主站蜘蛛池模板: 锡林浩特市| 乐平市| 延长县| 博乐市| 根河市| 吴江市| 六枝特区| 遂宁市| 泉州市| 松阳县| 缙云县| 囊谦县| 宿州市| 天津市| 凭祥市| 南开区| 桓仁| 县级市| 镇康县| 丰原市| 荔波县| 小金县| 红安县| 铜鼓县| 伊金霍洛旗| 新蔡县| 闻喜县| 海伦市| 霍林郭勒市| 山东| 长垣县| 扎赉特旗| 博野县| 三门县| 蕲春县| 白城市| 化隆| 宜城市| 中超| 永安市| 微山县|