久久国产精品午夜一区_91精品國產高清久久久久久91_?级毛片免费全部播放_欧美色图在线视频一区二区三区_国产综合亚洲一区二区三区_中文字幕熟女网_国产精品男人爽免费视频_九九无码网战_亚洲日本三级电影在线观看_欧美日韩DVD手机在线不卡

北京祥生興業(yè)科技有限公司

中級會員·8年

聯(lián)系電話

13681184382

當(dāng)前位置:> 供求商機(jī)> 類固醇激素校準(zhǔn)品

類固醇激素校準(zhǔn)品
類固醇激素校準(zhǔn)品

更新時(shí)間:2025/7/6 21:00:08

訪問次數(shù):352

聯(lián)系我們時(shí)請說明是化工儀器網(wǎng)上看到的信息,謝謝!
分享
中級會員·8年
聯(lián)人:
張先生
話:
13681184382
機(jī):
13681184382
址:
北京市北京經(jīng)濟(jì)技術(shù)開發(fā)區(qū)同濟(jì)中路甲7號18幢A座1010
化:
www.xiangshengbio.com
網(wǎng)址:

掃一掃訪問手機(jī)商鋪

供應(yīng)簡介
供應(yīng)商:祥生興業(yè)規(guī)格:7x3ml(lyoph


詳細(xì)介紹

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應(yīng)商:

    祥生興業(yè)

  • 規(guī)格:

    7 x 3 ml (lyoph.)


    72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


    Order no.: 72038
    • 11-Deoxycortisol
    • 21-Deoxycortisol
    • Aldosterone
    • Corticosterone
    • Cortisol
    • Cortisone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
    Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
    Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
    Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
    11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
    21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
     
    n.d. = not determined, analytes under LOQ

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

    72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


    Order no.: 72039
    • 11-Deoxycorticosterone
    • 17-OH-progesterone
    • Androstenedione
    • Dehydroepiandrosterone (DHEA)
    • Dehydroepiandrosterone sulfate (DHEA-S)
    • Dihydrotestosterone (DHT)
    • Estradiol
    • Progesterone
    • Testosterone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
    11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
    DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
    DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
    Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
    Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

    5.33

    n.d. (< 0.026)
    17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
    Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
    Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
     n.d. = not determined (< LOQ)

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

溫馨提示:不可用于臨床治療。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
產(chǎn)品對比 二維碼 在線交流

掃一掃訪問手機(jī)商鋪

對比框

在線留言
主站蜘蛛池模板: 庆云县| 天镇县| 聊城市| 孝义市| 克拉玛依市| 江都市| 奉新县| 芦溪县| 广河县| 彭州市| 大足县| 密云县| 长宁县| 祁东县| 怀安县| 阿克| 兴国县| 牟定县| 陈巴尔虎旗| 治多县| 内丘县| 龙口市| 嵊泗县| 永新县| 宽甸| 乌兰察布市| 双峰县| 塔城市| 襄垣县| 额济纳旗| 南华县| 青铜峡市| 竹北市| 呈贡县| 中宁县| 深泽县| 泸溪县| 大邑县| 西藏| 尼勒克县| 保山市|