SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology

SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology, large capacity for various types of laboratory experiments by centrifugation of precision instruments。
This high-speed centrifuges used centrifuge rotor rotating centrifugal force generated by the powerful, to speed up the settling velocity of particles in the liquid, the samples of different sedimentation coefficient and buoyant density of the material separate, is a non-uniform system of liquid separation equipment.

Features:
1, attractive appearance, small size, fully functional
2, light weight, large capacity
3, simple, easy to use
4, stable, adjustable speed and can automatically adjust the balance
5, low temperature rise of high efficiency, wide adaptability
6, applies to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use.

Technical data:

1, time range 0-60
2, rated power: 200W
3, speed range :500-6000 r / min
4, centrifugal Capacity: 50ml * 6
5, the centrifugal force: 7250g
6, Dimensions (mm): length * width * height 380 * 280 *270

Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
(1).Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
(2).Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
(3).Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 ℃ ~ 60 ℃) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
(4).Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
(5) To ensure safety, be sure to use ground wire
(6).In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
(7).Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
(8). Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
(9). Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價
主站蜘蛛池模板: 太谷县| 临泉县| 绩溪县| 长治市| 年辖:市辖区| 盈江县| 潍坊市| 洪湖市| 外汇| 锦州市| 绍兴市| 三门峡市| 沂南县| 白朗县| 铜山县| 姜堰市| 遵义县| 保靖县| 诸暨市| 云南省| 翁牛特旗| 安塞县| 昌乐县| 讷河市| 新泰市| 鹿泉市| 平阳县| 淳化县| 宿松县| 中方县| 祁连县| 彝良县| 阿拉善左旗| 苏州市| 那曲县| 银川市| 郁南县| 渭源县| 兴隆县| 锡林郭勒盟| 西乌珠穆沁旗|